Q.raxx D107

Q.raxx D107

Digital Measurement Plug-in Module Q.raxx D107

Digital Measurement Plug-in Module Q.raxx D107

The Q.raxx product is based on the standardized 19” technology and is designed for measurements with a high level of flexibility,
reliability and accuracy. The range of applications starts from small stand-alone solutions up to networked multi-channel
applications in the field of stationary testing and assembly.

The wide range of available plug-in modules and the flexibility of the system configuration allows an optimized solution for each
single task. Up to 13 plug-in modules in one system plus a Controller Unit provide a powerful package with PAC functionality, logging possibilities and an Ethernet TCP/IP interface.

Conclusion:
Dynamic signal acquisition up to 100 kHz, inputs and outputs for all types of signals, galvanic isolation of inputs and outputs, multi-channel solutions, high density packaging and intelligent signal conditioning for all kind of test applications.

Most important features of the system:

◘ High density and flexibility
 
up to 13 plug-in modules in one system in any constellation,
 flexible plug selection
◘ Test Controller Q.station or Q.gate selectable
.   
Ethernet TCP/IP for configuration and data transfer,
 EtherCAT, internal memory expandable by USB device,
.   logging features, PAC functionality, IRIG synchronization
.   for details please see separate Test Controller data sheets
◘ Robust and reliable
.   
stable and compact aluminum housing, easy to carry
.   electromagnetic compatibility according EN 61000-4 and EN 55011
.   Temperature range -20 up to +60°C
 power supply 10 up to 30 VDC

Most important features of the plug-in D107:    

◘ 2 to 6 configurable digital inputs
.   
number of channel depend on configuration
.   counter, frequency, PWM, differential or single ended
◘ Adjustable thresholds 256 steps
.   
differential inputs in the range of -20 V up to + 20 V,
 single-ended inputs in the range of 0 V up to +26 V
◘ Frequency input
 
frequency measurement up to 1 MHz (Chronos method),
 direction detection
◘ Counter input
.   
up/down counter, quadrature counter with reference
  zero recognition,up to 1 MHz
◘ PWM input
 
measurement of duty cycle and frequency, output with
.   variable frequency and/or duty cycle

Datasheet Q.raxx D107

Heeft u een vraag over dit product?